- Open “Further Functions” sub-menu from main menu -> open “Interval” page.
- Select/click on out of 6 possible interval slots.
- Select a time interval (1-60 mins) via the fader bar.
- The name of the interval can be changed by clicking into the text field. If the name is not changed, the automatically assigned default name will remain.
- Additionally, select smart blink: select toggle button on the right side on the screen to on position (it turns red). Smart blink will result in accumulative interval blinks -> the light turns off and on as many times as the number of intervals that have passed by. For example, with 10 mins interval and smart blink selected: 1x blink after 10 mins, 2x blinks after 20 mins, 3x blinks after 30 mins and so on.
- Store interval.
- Go to switch-profile menu and assign the created interval to a light function of an existing or new switch-profile (see also “Switch-Profiles”).
- After sending the switch-profile successfully to the lamp, the interval can be activated by selecting the associated light function via the physical switch of the lamp. The interval starts directly together with the light function and stops, as soon, as the lamp is being switched off or a different light function is selected.
- When boost or any special function is started during interval, the interval stops and will start new, after boost function or special function ends.